Model: | BSC-1100/1300/1500/1800IIB2-X | Tested Opening: | Safety Height 200 Mm |
---|---|---|---|
Highlight: | ISO biological safety cabinet class 2,SS304 biological safety cabinet,safety cabinet laboratory germfree |
BSC-1100 BSC-1300 II A2 Biosafety Cabinets 100% Air Exhausting Class II B2 Biological Safety Cabinet
Applications:
BSC Biological Safety Cabinet is a kind of necessary equipment in laboratories of microbiology, biomedical science, genetic recombination, animal experiment, and biological products. It plays a significant role especially in the occasion where protective actions are needed for operators, such as pharmaceutical analysis, healthcare and biomedical research. This equipment provides a germ-free and dust-free working environment during bacterial culture.
Features:
- Time reserve function.
- Motorized front window.
- ULPA filter life and UV life indicator.
- Automatic air speed adjustable with filter block.
- With memory function in case of power-failure.
- Work area surrounded by negative pressure, it can ensure maximum safety in work area.
- Most accessories are standard, which saves your money. There is no need to pay more.
- Audio and visual alarm (filter replacement, window over height, abnormal air flow velocity, etc).
- Remote control. All functions can be realized with it, making the operation much easier and more convenient.
- Interlock function: UV lamp and front window; UV lamp and blower, fluorescent lamp; blower and front window.
- Foot switch. Adjust front window height by foot during experiment, to avoid airflow turbulence caused by arm movement.
Model Specification:
Model | BSC-1100IIB2-X | BSC-1300IIB2-X | BSC-1500IIB2-X | BSC-1800IIB2-X | |
Internal Size(W*D*H) | 940*600*660 mm | 1150*600*660 mm | 1350*600*660mm | 1700*600*660 mm | |
External Size(W*D*H) | 1100*750*2250mm | 1300*750*2250mm | 1500*760*2250mm | 1873*775*2270mm | |
Tested Opening | Safety Height 200 mm(8’’) | ||||
Max Opening | 420mm(17’’) | 420mm(17’’) | 500mm(20’’) | 480mm(20’’) | |
Inflow Velocity | 0.53±0.025 m/s | ||||
Down flow Velocity | 0.33±0.025 m/s | ||||
Pre-Filter | Washable | ||||
ULPA Filter | Two, 99.9995% efficiency at 0.12 μm,filter life indicator. | ||||
Front Window | Motorized,two-layer laminated toughened glass ≥ 5mm,anti UV. | ||||
Noise | NSF49 ≤ 61 dB / EN1246949 ≤ 58 dB | ||||
UV Lamp | 30W*1 | 30W* 1 | 40W* 1 | 40W*1 | |
UV timer, UV life indicator, emission of 253.7 nanometers for most efficient decontamination. |
|||||
Illuminating Lamp | LED Lamp | LED Lamp | LED Lamp | LED Lamp | |
12W*2 | 14W*2 | 16W*2 | 16W*2 | ||
Illumination | ≥1000Lux | ||||
Consumption | 700W | 850W | 900W | 1200W | |
Waterproof Sockets | Two, total load of two sockets: 500W | ||||
Display | LCD display: exhaust filter and downflow filter pressure, filter and UV lamp working time, inflow and downflow velocity, filter life, humidity and temperature, system working time etc. | ||||
Control System | Microprocessor | ||||
Airflow System | 0% air recirculation, 100% air exhaust | ||||
Alarm | Abnormal airflow velocity; Filter replacement; Front window at unsafe height. | ||||
Exhaust Duct | 4 meters PVC duct, Diameter:300mm | ||||
Material | Work Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria powder coating. |
||||
Work Surface Height | 750mm | ||||
Caster | Foot master caster | ||||
Power Supply | AC 220V±10%, 50/60Hz; 110V±10%, 60Hz (110V/60Hz is not applicable to BSC-1800IIB2-X) | ||||
Standard Accessory | Illuminating lamp, UV lamp*2,base stand, remote control, foot switch, exhaust blower, exhaust duct, drain valve, waterproof sockets*2, pipe strap*2 |
||||
Optional Accessory | Water and gas tap, Electric height adjustable base stand | ||||
Gross Weight | 246kg | 276kg | 302kg | 408kg | |
Package | Main Body | 1230* 990* 1810 mm | 1460*1050*1800 mm | 1650*990*1810 mm | 2020*1080*1900 mm |
Exhaust Blower (W*D*H) | 970* 810* 630 mm | 970* 810* 630 mm | 970* 810* 630 mm | 970* 810* 680 mm |
Three protection: operator, sample and environment.
Airflow system: 0 % air recirculation, 100% air exhaust
A Class II B2 BSC, also called a total exhaust cabinet, is necessary when significant amounts of radionuclides and volatile chemicals are expected to be used.
FAQ 1. Are you a factory or trading company?
We are a factory.
FAQ 2. Can you supply OEM?
OEM is available.
FAQ 3. What's the MOQ ?
(1). MOQ is 1 piece. The disposable supplies order usually at least 1 box.
FAQ 4. How about the order processing and lead time?
After order confirmation and receive the advance payment, we will prepare the machines and goods. Usually could ready within 10 working day, when dispatch, will inform client and send the documents for client making import customs clearance.
FAQ 5. What quality will be ensured?
100% new and quality inspection before delivery from factory.
Stable export box for good package.
FAQ 6. Can you guide the working?
The machine will deliver with English display, English manual and video for installation and operation.
FAQ 7. How can your engineer replace parts if they are not beside the machine?
Bonnin’s engineer could provide the solutions by email and video. In warranty period, we can send spare parts for free and life-time technical support for spare supply.